Test UD 001
We recommend to visualize signals
- in_IgnSwitch
- in_TurnIndLvr
- pwmRatio_FL
- pwmRatio_FR
It can be seen how the turn indicator lever in_TurnIndLvr is activated in position LEFT=1 for about 54ms (just long enough
for the signal to be declared valid during the debouncing phase)
after the ignition (in_IgnSwitch) has been switched on (status 4). The short activation of the turn indicator
lever triggers the tip flashing functionality (see state machine SystemUnderTest.NormalAndEmerFlashing.LeftRightFlashing
in the
turn indicator model). Tip flashing forces 3 flashing periods to be performed before the turn indication
on the left-hand side is switched off again (pwmRatio_FL = 0).