When the water pressure is greater than or equal to 9, and the water pressure was not greater than or equal to 9, and the pressure mode is low, the Safety Injection System shall assign permitted to the pressure mode.
When the water pressure is greater than or equal to 10, and the water pressure was not greater than or equal to 10, and the pressure mode is permitted, the Safety Injection System shall assign high to the pressure mode.
When the water pressure is lower than 9, and the water pressure was not lower than 9, and the pressure mode is permitted, the Safety Injection System shall assign low to the pressure mode.
When the water pressure is lower than 10, and the water pressure was not lower than 10, and the pressure mode is high, the Safety Injection System shall assign permitted to the pressure mode.
When the blockage sensor is on, and the blockage sensor was off, and the reset sensor is off, and the pressure mode is not high, the Safety Injection System shall assign on to the overridden mode.
When the reset sensor is on, and the reset sensor was not on, and the pressure mode is not high, the Safety Injection System shall assign off to the overridden mode.
When the pressure mode is high, and the pressure mode was not high, the Safety Injection System shall assign off to the overridden mode.
When the pressure mode is not high, and the pressure mode was high, the Safety Injection System shall assign off to the overridden mode.
When the pressure mode is low,
... and the overridden mode is on, the Safety Injection System shall assign off to the safety injection mode.
... and the overridden mode is off, the Safety Injection System shall assign on to the safety injection mode.
When the pressure mode is permitted or the pressure mode is high, the Safety Injection System shall assign off to the safety injection mode.